• SPEED
    QUALITY SUPPLIERS
    EASY NAVIGATION
    QUICK RESPONSES
    DIRECT SHIPMENTS
    GLOBAL SUPPORT

  • EXCELLENCE
    QUALITY SUPPLIERS
    PROMPT SERVICE
    SA
    TISFACTION IS
    #1 PRIORITY

  • ECONOMICS
    LOWEST PRICES
    FREE FREIGHT
    QUICK DELIVERIES

  • KNOWLEDGE
    FACTORY TRAINED
    OTJ EXPERIENCE
    ENGINEERING SUPPORT

SEALLESS PRESSURE REGULATING VALVES

 

Sealless Pressure Regulating ValveC Series Wanner™ pressure regulating valves bypass system fluid to prevent excess system pressure. When a system discharge is completely closed – such as a closed spray gun, closed valve or plugged nozzle – Wanner™ pressure regulating valves bypass the total system fluid flow. They also balance system pressure for multiple-orifice operations, essentially "regulating" the system pressure through bypassing of "excess" fluid.Internals of a C Series pressure regulating valve

 

The Wanner™ pressure regulating valve design consists of a spring loaded tapered plunger against a valve seat. When the system pressure overcomes the adjustable spring pressure holding the plunger against the seat, the plunger lifts off the seat just enough to ensure the system pressure doesn't exceed the set maximum.  With the plunger lifted partly off the seat some or all of the fluid will bypass the discharge line; perhaps to the feed tank, inlet line or to drain. The internal design has baffles to gently direct flow around the plunger and seat interface to reduce erosion wear.

 

The sealless design of our pressure regulating valve eliminates the potential of fugitive emissions (leakage) and thus is ideal for hazardous fluids containing particulates.

 

The plunger assembly and valve seat are easily removed when worn, simply remove the top of the body and replace the worn components. The valve can be serviced in place without disturbing any fittings or plumbing.

 

Features
• Ideal for high pressure, dirty fluids
• Sealless, flow-through design
• Heavy-duty construction
• Immediate response
C20 Catalog Page (C20 IOM)
C46 Catalog Page (C46 IOM) (C46 Parts Manual)
C60 Catalog Page (C60 IOM)

 

We will specify which pressure regulating valve to use with the corresponding Wanner™ Hydra-Cell® Pro pump.